SILENT KNIGHT 4821 Manual de usuario Pagina 2

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 4
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 1
4815 Smart Sensor
Controller Zone Expander
Connects to the S-Bus on the 4821
control and allows expansion of the
4821 up to 400 zones. The 4815 can
be mounted in the snap track in the
4821 cabinet or remotely mounted in
a plastic utility enclosure. Each 4815
has two serial loops, each capable of
supporting up to 64 SmartSensor
devices for a total of 128 points. Up
to three 4815 controllers may be
used with the 4821. SmartSensors
point ID modules allow connection to,
and point identification of, most
security devices. SmartSensors can
also monitor
non-security contact type devices as
well. SmartSensor addresses are
programmed on-site through a
system touchpad. Point
characteristics are defined by
program options set in the 4821. The
two serial loops are
electronically protected against
shorting and if one loop is shorted,
the other continues to operate
normally. Removing the short
restores loop
functioning automatically.
Dimensions:
048150 4.0" H x 5.25" W (board only)
4815 6.0" W x 7.875" H x 1.5" D
(plastic enclosure)
Shipping Weight:
8 oz.
Power requirements:
11 to 14VDC at 80mA
(provided by 4821)
Loop wiring distance:
3,000 feet using 22 gauge wire
5,000 feet using 18 gauge wire
4111P SmartSensor Devices
Connect to serial loops on the 4815
SmartSensor controller module. Up to
64 devices may be connected on
each loop for a total of 128 points per
4815. SmartSensor point ID modules
are addressed on-site using a system
touchpad. SmartSensors are
available as a stand alone device for
connection to any contact type
sensor.
4824 Serial/Parallel Module
Connects to the S-Bus on the 4821
control and provides both an RS-232
serial port and a Centronics parallel
port. Up to eight 4824 modules may
be connected to a 4821 system
allowing for separate printers in each
partition. The 4824 may be located
anywhere along the S-Bus which
allows printers to be conveniently
located. Reports may be filtered to
print only the data required for a
particular partition. Printed
information may also be filtered by
event type as required. The 4824
allows connection of a portable
computer, on-site, for programming
the system. Connecting an external
modem and phone line to the 4824
allows remote up/downloading to take
place at up to 19,200 bps.
Dimensions:
6.0" W x 7.875" H x 1.5" D
(plastic enclosure)
Shipping weight:
3 lbs.
Power requirements:
11 to 14VDC at 20mA
(supplied by 4821)
Accessories:
Parallel printer (not supplied by
Silent Knight), external modem
(not supplied by Silent Knight).
Security System Features
16 programmable zones,
expandable to 400.
Two types of zone expansion,
hardwire or multiplex point.
Zone expanders may be remotely
located from control.
Up to 6 zone expanders may be
used per system.
1,800 users, codes and cards.
8 true partitions, with up to 8
areas per partition.
High speed 4-wire supervised
serial bus for connection of
touchpads, zone expanders, and
other accessories.
Highly ef ficient switching type 2.5
amp power supply.
Up to 24 touchpads or readers
total may be used per system.
Non-volatile flash memory.
500 event memory.
Four unique sounding patterns.
64 separate exit delays, one for
each area. Entry delay by zone.
Two separately controllable
interiors per area.
Code 2 feature (temporary code).
Duress feature.
Time window programming for
restricted use.
Automatic daylight savings
adjustment.
Service reminder.
Programmable I/O for use with
output modules.
Output modules provide up to 60
voltage/relay outputs.
Built-in line fault monitor .
Program on-site or remotely over
telephone line.
Reports in SIA and Contact ID
formats.
Listings & Approvals:
UL Residential Household Burglary
and Fire (UL985, UL1023) NFPA 72,
Chapter 2
UL Commercial Grade A Local
Mercantile, Grade B & C Central
Station Reporting (UL365, UL609,
UL1610, UL1635)
California State Fire Marshal
Residential Fire (7167-559:124)
Model 4821 Integrated Access
Control and Security Accessories
integrated access control and security system
Vista de pagina 1
1 2 3 4

Comentarios a estos manuales

Sin comentarios