Series 5000 Entry System Installation/Operation Manual
3-4 151174
3.1.4 Board Components Description
3.2 Mounting Instructions
This section contains information necessary to properly mount the 5083, and 5084 panels.
Avoid installing the 5083 and 5084 in a high noise environment such as a noisy lobby or
outside where there is a large amount of traffic or airplane noise.
Do Not mount the 5000 series units in locations subject to high temperatures, such as over
a lobby heater.
Be sure to seal any openings into the entry system back box that connect to the interior
walls. This is to prevent water damage that could occur if warm moist air entered the back
box and condensed on the board surfaces.
The operating temperature range must be between 0° C and +50° C (32° F and +120° F) or
humidity outside the range of 10%-85% at 86° F (30° C) non-condensing. With the
addition of the model 5076 Heater Kit, the operating temperature range can be extended to
between -28° C and +50° C (-20° F and +120° F). (See Section 3.6.1.)
Note: The 5000 Entry System is designed for use in a sheltered outdoor environment and the system circuitry will
operate normally in the temperature ranges listed.
Table 3-1: Terminal Descriptions
Terminal
No.
Name Description
1AC 1
AC power input connections.2AC 2
3EARTH
4COM
Door Relay connections.
5NO
6COM
Auxiliary relay connections.
7NO
8 DOOR Door reset.
9 AUX Aux reset.
10 +12 Positive 12 VDC @ 100 mA used for alarm output.
11 GND
SBUS for satellite connections.
12 +
13 A
14 B
15 RING
Telephone line connections.
‘TIP