Series 5000 Entry System Installation/Operation Manual
4-12 151174
0
(Cont.)
SYSTEM MESSAGE
ENTER APT #
ENTER SUITE #
ENTER UNIT #
ENTER CODE #
ENTER
APT #
Change the display message to accommodate the
installation site. (See 4.2.1 step 26 for step-by-step
instructions.)
AUX RELAY
Enabled, Alarm,
Ground Start or
Disabled
Disabled If enabled the aux relay is operational. If Alarm is
selected the auxiliary will be used as an alarm output.
If ground start is selected the auxiliary relay will be
used for phone systems that use ground start phone
operations. If disable the auxiliary relay will not
operate. (See 4.2.1 step 28 for step-by-step
instructions.)
AUX TIME
WINDOW
Enabled, Disabled, or
Continuous
Disabled If this feature is enabled the system will make the
auxiliary relay operable during the programmed time
window. The time window On/Off times are
programmed in the Operating Mode 2 “Time Set.
(See Section 4.2.1 step 30 for step-by-step
instructions.) Continuous means that the relay will be
energized for the entire Aux Time Window.
SPEAKER VOLUME
LOW
MEDIUM
HIGH
LOW This feature selects the volume of the system
speaker. This allows you to adjust the speaker
volume to facilitate the installation environment.
ANSWER RINGS
0 - 15 3 This feature set the number of rings before the
control panel will answer the phone to begin
communication with the up/down loading software.
1 User Options
USER NUMBER Blank Enter the number of the user as listed on user
directory. See Section 4.2.2 for step-by-step
procedure.
USER PHONE Blank Enter the phone number to the user’s office/
apartment. See Section 4.2.2 for step-by-step
procedure.
USER CODE Blank Enter the code the user will use for keyless entry. See
Section 4.2.2 for step-by-step procedure.
DIAL PBX No If the users phone number requires a PBX access
number (see Operating Mode 0) dialed before dialing
select Yes. See Section 4.2.2 for step-by-step
procedure.
DOOR ACCESS No Yes, enables keyless entry for the user being
programmed. No, disables keyless entry for that user.
See Section 4.2.2 for step-by-step procedure.
AUX ACCESS No Yes, allows the user to energize the aux. relay with a
9 from user phone.
2Time Set
Sets the real-time clock and auxiliary enable /disable
times.
See Section 4.2.3 for step-by-step procedure.
3 Activate Door Relay See Section 4.2.4 for step-by-step procedure.
4
Activate Auxiliary
Relay
Disabled See Section 4.2.5 for step-by-step procedure.
5 Telephone operation
Enter number of
location you wish to
call. Press # to hang
up.
N/A Makes the 5083/5084 Control Panel into a normal
telephone.
See Section 4.2.6 for step-by-step procedure.
6 CLR MEMORY Yes or No No See Section 4.2.7 for step-by-step procedure.
Table 4-2: Quick Chart
Operating
Mode
Display Shows/
Feature
Choices Default Comments