Testing and Troubleshooting
151174 5-3
5.3 Troubleshooting
This section contains information that will help avoid problems down the road in an
installation site as well as standby voltage readings and error messages.
5.3.1 To Avoid Problems
Telephones without polarity protection will operate the system 50% of the time. The
telephone company will correct this problem after you contact them. Any TouchTone
phones manufactured before 1975 may be affected.
Telephone systems using a “concentrator” will not generate a large enough pulse to be
decoded when using rotary telephones. If these symptoms occur call the telephone
company to verify if a “concentrator” is being used.
Do not share telephone lines when using the 5000 Entry System.
Wire runs to satellite units from the master unit should not exceed guide lines described in
Section 3.5.6.
Figure 5-1 Block diagram of the 5000 Entry System Hub
Never connect the remote satellite units while power is supplied to the control panel. If an
attempt is made to install a satellite with “hot” wires, the equipment may be damaged.
Only one unit in the system can be used as a Master unit all other units must be
programmed as a satellite unit (see Figure 5-1). Each satellite unit must use a unique
SBUS ID. (See Section 3.5.7 for wiring and configuring a master and satellite panels.)
All connections made between the control panel and the remote satellites must be tight.
Any loose connections WILL cause problems.
Any splice points should be soldered not crimped.
If frequent or lengthy power outages are expected, it may be necessary to add more battery
capacity. This will increase the time the system will operate without AC power.