Programming
150966 6-19
Alarm Reporting Delay
Time
This option programs the duration of the delay before alarms on zones
programmed as Delayed Reporting are reported to the central station.
If an alarm is reset before the alarm delay reporting occurs the central
station will receive no indication of the alarm, but will receive an
open-reset.
Range is 0 - 15 seconds. This option must be disabled (set to 0) in UL
installations.
1
The next two options control Swinger Bypass, a false alarm prevention
feature. If a zone has been selected as swinger bypass, it means that a
specified number of alarms occurring within a specified time frame
will cause the zone to be automatically bypassed. You must program
both the number of alarms that can occur within the time frame and the
duration of the time frame.
Note: If you program a number other than zero for Swinger Bypass
Timeout, Swinger Bypass Maximum Value should not be zero.
Swinger Bypass Maximum
Value
Enter the number of alarms that can occur within the swinger bypass
time-out period before the zone will be automatically bypassed. Range
is 0 - 255. A typical selection is 4. (Use the next option to program the
duration of the swinger bypass time-out period.)
0
Swinger Bypass Timeout Enter the number of minutes for the swinger bypass time-out period. If
a specified number of alarms occurs within this period, the zone will
be bypassed automatically. Note that the zone must be selected as
bypassable. Range is 0-255 minutes. Enter 0 here to disable the
swinger bypass feature.
0
Duress trigger code Enter two-digit duress trigger code that will call the central station in a
duress situation without causing audible or visible indication.
Entering this code as a prefix to a user code causes the system to notify
the central station that an intruder has forced the user to enter an access
code. A holdup alarm code is sent to the central station using the ID
number.
The valid 2-digit range is 00-99. If no digits are entered, the duress
option is disabled.
Note: the 2-digit sequence must not be used any place in the user
codes.
[blank]
Table 6-5: Partition Options and Description
Option Description Default